  1. Zhou W, Malave MN, Maloney JA, White C, Weinman JP, Huo D, Neuberger I. Radiation dose reduction using spectral shaping in pediatric non-contrast sinus CT. Pediatr Radiol. 2023 09; 53(10):2069-2078.
    View in: PubMed
    Score: 0.451
  2. Zhou W, Michalak GJ, Weaver JM, Gong H, Yu L, McCollough CH, Leng S. A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System: A Feasibility Study. Invest Radiol. 2020 04; 55(4):226-232.
    View in: PubMed
    Score: 0.361
  3. Zhou W, Bartlett DJ, Diehn FE, Glazebrook KN, Kotsenas AL, Carter RE, Fletcher JG, McCollough CH, Leng S. Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration. Invest Radiol. 2019 04; 54(4):204-211.
    View in: PubMed
    Score: 0.337
  4. Tao S, Rajendran K, Zhou W, Fletcher JG, McCollough CH, Leng S. Noise reduction in CT image using prior knowledge aware iterative denoising. Phys Med Biol. 2020 11 19; 65(22).
    View in: PubMed
    Score: 0.094
  5. Rajendran K, Voss BA, Zhou W, Tao S, DeLone DR, Lane JI, Weaver JM, Carlson ML, Fletcher JG, McCollough CH, Leng S. Dose Reduction for Sinus and Temporal Bone Imaging Using Photon-Counting Detector CT With an Additional Tin Filter. Invest Radiol. 2020 02; 55(2):91-100.
    View in: PubMed
    Score: 0.089
  6. Tao S, Rajendran K, Zhou W, Fletcher JG, McCollough CH, Leng S. Improving iodine contrast to noise ratio using virtual monoenergetic imaging and prior-knowledge-aware iterative denoising (mono-PKAID). Phys Med Biol. 2019 05 16; 64(10):105014.
    View in: PubMed
    Score: 0.085
  7. Gong H, Yu L, Leng S, Dilger SK, Ren L, Zhou W, Fletcher JG, McCollough CH. A deep learning- and partial least square regression-based model observer for a low-contrast lesion detection task in CT. Med Phys. 2019 May; 46(5):2052-2063.
    View in: PubMed
    Score: 0.084
  8. Leng S, Rajendran K, Gong H, Zhou W, Halaweish AF, Henning A, Kappler S, Baer M, Fletcher JG, McCollough CH. 150-?m Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology: Technical Performance and First Patient Images. Invest Radiol. 2018 11; 53(11):655-662.
    View in: PubMed
    Score: 0.082
  9. Leng S, Zhou W, Yu Z, Halaweish A, Krauss B, Schmidt B, Yu L, Kappler S, McCollough C. Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets. Phys Med Biol. 2017 Aug 21; 62(17):7216-7232.
    View in: PubMed
    Score: 0.075
  10. Gong H, Tao S, Rajendran K, Zhou W, McCollough CH, Leng S. Deep-learning-based direct inversion for material decomposition. Med Phys. 2020 Dec; 47(12):6294-6309.
    View in: PubMed
    Score: 0.024
  11. Zhu XY, Zou X, Mukherjee R, Yu Z, Ferguson CM, Zhou W, McCollough CH, Lerman LO. Targeted Imaging of Renal Fibrosis Using Antibody-Conjugated Gold Nanoparticles in Renal Artery Stenosis. Invest Radiol. 2018 10; 53(10):623-628.
    View in: PubMed